Katalog_2024_Lacont_englisch

Frost-free storage for SLT type: 4 x 6 4 x 8 / 5 x 8 Active storage Article no. H63-9071-A H63-9072-A Convection heating, ex-proof, 6,9 kW / 9,3 kW / T3, incl. collision protection 400 V 400 V 157 ACCESSORIES FOR SAFETY STORAGE HOUSES FITTINGS FOR SAFETY STORAGE HOUSES SLH / SLH-NB / SLT Frost-free storage for SLT type: 1 x 2 / 2 x 2 / 3 x 2 6 x 2 / 6 x 3 5 x 6 / 4 x 8 4 x 2 / 5 x 2 / 4 x 3 5 x 4 / 4 x 6 5 x 8 Article no. H63-9020-A H63-9080-A H63-9081-A Frost-free storage for SLT type: 1 x 2 / 2 x 2 / 3 x 2 6 x 2 / 6 x 3 5 x 6 / 4 x 6 4 x 8 / 5 x 8 Passive storage 4 x 2 / 5 x 2 / 4 x 3 5 x 4 Frost-free storage for SLT type: 1 x 2 / 2 x 2 5 x 2 / 6 x 2 6 x 3 5 x 4 / 5 x 6 Active storage 3 x 2 / 4 x 2 4 x 3 Article no. H63-9002-A H63-9003-A H63-9009-A H63-9011-A LED Moisture-proof lamp 230 V, 43 W, Article no. H61-9009-E * According to TRGS 510, a technical exhaust air monitoring system is to be installed in the case of at least two-fold air exchange (active storage)! Lighting Article no. For the passive storage of flammable liquids Article no. For the active storage of flammable liquids Article no. LED Moisture-proof lamp 230 V, 43 W H61-9009-E LED Lamp ex-zone II, 230 V, 40 W, effective luminous flex 6430 lm H61-9090-B Technical forced ventilation ex-proof (wall ventilator) 230 V / 50 Hz H61-9006-C LED Lamp ex-zone I, 230 V, 40 W, effective luminous flex 6290 lm H61-9091-B Technical forced ventilation ex-proof (tube fan) H61-9026-B Exhaust air monitoring incl. flow sensor and signal horn for alarming* H61-9053-B Potential equalizing bar on the outside of the container as per DIN VDE H63-9031-A With regard to explosion protection requirements, a distinction must always be made between the storage of water-endangering and flammable liquids. Electrical fittings (premounted) 1. For the storage of water-endangering liquids When storing water-hazardous liquids, e.g. oils, lubricants, greases, etc., there are no special requirements for the explosion protection of the electrical installations. 2. For the storage of flammable liquids When storing flammable liquids, e.g. paints, solvents, etc., a distinction is made between passive and active storage (see TRGS 509/510). 2.1 In the case of passive storage, no filling activities are carried out within the storehouse. In order to achieve the required air exchange, natural or technical ventilation (0.4 to 2-fold air exchange) is required. 2.2 In the case of active storage, filling activities are carried out within the storehouse. In order to achieve the required air exchange a technical forced ventilation (> 5-fold air exchange) is required only. Technical forced ventilation, ex-proof, Article no. H61-9006-C Exhaust air monitoring, Article no. H61-9053-B Heating, ex-proof, 2 kW / 230 V, Article no. H63-9002-A Potential equalizing bar, Article no. H63-9031-A Switch box, Article no. H63-9007-A Optional plug connection for SLH combination Switch box Article no. All electrical fittings wired up to switch box H63-9007-A ◆ ◆ ◆ IP 65 attached to the outside of the storehouse Incl. complete wiring of the electrical fittings To accommodate all fuses and controls Plastic switch box Heating ex-proof, T3 2 kW / 3 kW / 2 x 2 kW / 2 x 3 kW / incl. collision protection 230 V 230 V 230 V 230 V Convection heating, not ex-proof, incl. collision protection 2 kW / 230 V 3 kW / 230 V 5 kW / 400 V Convection heating 2 kW, not ex-proof, Article no. H63-9020-A LED Lamp ex-zone II, 230 V, 40 W, Article no. H61-9090-B When using insulation of the base sump tray we guarantee a frost-free storage up to an outside temperature of -15°C!

RkJQdWJsaXNoZXIy NzgwNTU=