Pro-Modell LaCont battery cabinet
Safe Pro lithium-ion battery cabinet
Safe Pro battery cabinet: Pro model with GS certification
The Safe Pro Battery Cabinet LaCont is the ideal safety solution for the active and passive storage of lithium-ion batteries (rechargeable batteries)
Battery cabinet Li-Ion Safe Pro
- A Pro model specially designed for the active and passive storage of lithium-Ion batteries (rechargeable batteries), with GS certification in accordance with the test criteria EK5 / AK4 22-01 and the real-fire test carried out on the lithium-ion-A cabinet fitted with batteries (rechargeable batteries) at the MPA Dresden
- Tested fire resistance of 90 minutes in accordance with DIN EN 14470-1 from the outside in
- Fire resistance of 90 minutes from the inside out DIN EN 1363-2
- GS mark from MPA Dresden Audited in accordance with audit standard EK5 / AK4 22-01
- Tested smoke-tightness
- Self-closing doors, tested for long-term functionality in accordance with DIN EN 16121 and DIN EN 16122
- Construction using non-combustible building materials, including a coating
- Perimeter fire protection seals that automatically foam up in the event of a fire
Product information
Product information for the Safe Pro battery cabinet
| Features | SiS Li-Ion 90 Safe Pro |
|---|---|
| Fire resistance class | 90 minutes |
| Internal fire resistance | 90 minutes (in accordance with EN 1363-2) |
| External fire resistance | 90 mins (in accordance with EN 14470) |
| Basis for audit | EK5/AK4 22-01 |
| Certification | GS certificate |
| Maximum charge energy | Max. 12 kWh recommended (for standard batteries only) |
| Maximum charge energy in accordance with VDMA 24994 | – |
| Can be charged in the cupboard | optional |
| Number of charging points | 0 / 2 / 4 |
| Maximum charging power per cabinet | 3.5 kW at 230 V and 10.5 kW at 400 V |
| Integrated pressure relief | – |
| integrated mechanical ventilation | yes |
| self-closing doors | yes (permanent) |
| Control unit | As standard |
| Smoke detectors / Fire detection | As standard |
| Mechanical ventilation | As standard |
| Shutting off the ventilation in the event of a fire | As standard |
| visual and audible status indicators | yes |
| visual and audible alarms in the event of a fire | yes |
| Shutdown in the event of an emergency | Yes – full power supply |
| Active fire suppression | Optional |
| voltage-free interface | yes |
| Cable entry possible | – |
| pre-installed cable for the customer’s fire alarm | yes |
| Locking system | Door handle with profile cylinder (compatible with locking systems) |
| Number of grating floors | 4 |
| Number of steel shelves, powder-coated | 0 |
| Load-bearing capacity of the floors | 75 kg |
| base with clearance for vehicles to pass underneath | yes (100 mm) |
| floor pan | yes (5 litres) |
| Surge protection | yes |
| Supply voltage | 230 V or 400 V |
- A Pro model specially designed for the active and passive storage of lithium-Ion batteries (rechargeable batteries), with GS certification in accordance with the test criteria EK5 / AK4 22-01 and the real-fire test carried out on the lithium-ion-A cabinet fitted with batteries (rechargeable batteries) at the MPA Dresden
- Tested fire resistance of 90 minutes in accordance with DIN EN 14470-1 from the outside in
- Tested fire resistance of 90 minutes from the inside out, in accordance with DIN EN 1363-2
- GS mark from MPA Dresden audited in accordance with the audit principles EK5 / AK4 22-01
- Tested smoke-tightness
- Self-closing doors, tested for long-term functionality in accordance with DIN EN 16121 and DIN EN 16122
- Constructed from non-combustible materials, including a coating (body in RAL aluminium colour / doors in RAL 1023 – traffic yellow)
- Perimeter fire protection seals that automatically foam up in the event of a fire
- Double-leaf door with a central mullion, lockable with a profile cylinder lock; cupboard doors close automatically
- Includes technical ventilation (to prevent heat build-up inside the cabinet)
- Base with space underneath, height 100 mm, with removable base panel
- Storage levels with height-adjustable mesh shelving, load capacity 75 kg per level
- Includes floor tray in accordance with AwSV, powder-coated sheet steel in RAL 7035 – light grey, capacity 5 litres
- Each grating level can be fitted with a power strip featuring 10 earth-connected sockets
- Equipped as standard with a control unit (visual and audible status indicators), fire detection and smoke detectors)
- Complete disconnection of the power supply to the cabinet in the event of an emergency
- Surge protection
- Operating voltage 230 V or 400 V (the version without a power strip is available in 230 V only)
- Control unit of the SiS Li-Ion 90 Safe Pro
- Power switch
- Visual status indicator
- If a fire is detected inside the cabinet, the power supply and the integrated ventilation system are switched off completely
- If a fire is detected, a visual and audible alarm is triggered
- Includes a potential-free contact for signal transmission (e.g. to a control centre)
- Including cable preparation (inside and outside) for the subsequent installation of a Fire alarm sensor for installation on the customer’s premises, for connection to a fire alarm system
- Optional GSM module for remote monitoring and alarm notification
- Operating voltage 230 V, fuse rating: 1-phase 16 A
- Maximum electrical power per charging cabinet for the 230 V version: 3.5 kW (max. 2 kW per power strip)
- Operating voltage 400 V, 3-phase fuse protection 3 x 16 A
- Maximum electrical power per charging cabinet for the 400 V version: 10.5 kW (max. 3.5 kW per power strip; for the version with 4 x power strips, the top two power strips each rated at 3.5 kW, the bottom two each rated at 1.75 kW)
Aerosol fire-extinguishing generator: The optional integrated aerosol extinguishing generator activates automatically in the event of a critical rise in temperature or a fire. The extinguishing aerosol fills the interior in a matter of seconds, effectively suppressing the flames and preventing the fire from spreading to neighbouring batteries

Power strip: The power strip installed in the cabinet enables the organised and safe charging of several lithium-ion batteries at the same time. It ensures a neat power supply directly to the storage levels

Integrated floor pan: An integrated drip tray ensures that, in the event of damage to the cells, no environmentally hazardous liquids can escape uncontrollably

Control unit with smoke detection and visual status indicator: If a fire is detected inside the cabinet, the power supply and the integrated ventilation system are switched off completely. A clearly visible indicator allows you to see the current operating status (e.g. normal operation, fault or alarm) at a glance at any time, without having to open the cabinet.

Can be accessed with a pallet truck: Thanks to its 100 mm high, wheelchair-accessible plinth, the fireproof cabinet can be transported using a pallet truck or forklift truck

Integrated ventilation: To effectively prevent dangerous heat build-up during charging in normal operation, an integrated ventilation system ensures constant air circulation

Automatic door closer: An automatic door-closing mechanism ensures that the cabinet doors do not remain open accidentally during day-to-day use. In the event of a fire, the doors also lock automatically, thereby immediately activating the fire protection function of the 90-minute enclosure without the need for manual intervention
LaCont Battery Cabinets | Fire safety „Made in Germany“
When it comes to the safe storage and charging of lithium-ion batteries, the LaCont Umwelttechnik GmbH for maximum safety. Our high-quality battery cabinets bear the seal of quality „Made in Germany“ with a reliable 90-minute fire resistance. This protects your staff, prevents the fire from spreading to the building and gives the emergency services valuable time to respond. As our safety cabinets are developed and manufactured in Germany, we guarantee that (Basic, Safe Pro and Premium) The highest manufacturing quality, safety in accordance with standards and maximum reliability in day-to-day industrial use.
Our Safe Pro model ensures maximum, officially certified operational safety thanks to the official GS Certificate (Certified Safety) the MPA Dresden,
1. How does the Safe Pro’s control unit respond in the event of a fire or smoke being detected?
In the event of an emergency, the cabinet automatically triggers a visual and an audible alarm
2. What level of protection and which security certifications does the Safe Pro offer?
The cabinet has been awarded the GS mark by MPA Dresden (tested in accordance with EK5 / AK4 22-01) and has passed a real-fire test there involving lithium-ion batteries
3. What type of electrical connection (230 V or 400 V) is required for operation?
-
230 V (single-phase, 16 A): Models without power strips are available exclusively in 230 V
. For versions with sockets, the maximum total electrical power is 3.5 kW (max. 2 kW per power strip) -
400 V (3-phase, 3 x 16 A): Provides a maximum electrical power output of up to 10.5 kW (max. 3.5 kW per power strip)
Safe Pro Battery Cabinet: GS-certified fire protection for battery storage
Lithium-ion batteries have become an integral part of our everyday lives. Lithium-ion rechargeable batteries are being used in an ever-increasing number of products and devices, not only in the private sector but also, in particular, in trades and industrial settings, such as in a wide range of power tools or mobile machinery. However, these high-performance rechargeable batteries pose significant risks if handled or stored incorrectly. A technical fault, mechanical damage or overcharging can lead to an uncontrolled fire that is very difficult to extinguish. There is still no valid legislation governing the storage of lithium-ion batteries (rechargeable batteries). Nevertheless, Li-ion rechargeable batteries should be treated as hazardous substances. Due to this high risk potential, the utmost care must be taken to ensure maximum safety when storing and charging lithium-ion batteries..
Protection objectives of the Safe Pro battery cabinet
The Safe Pro battery cabinet from LaCont offers maximum security for the active and passive storage of lithium-ion batteries. Wherever batteries are charged or stored in professional and commercial settings, standard fire protection is often no longer sufficient. This is precisely where the Pro model comes in, featuring the GS mark was awarded and a successful live-fire test has demonstrated. The cabinet was designed to meet all essential protection objectives in the event of an emergency:
- Protection of stored goods against fire from outside
- Protection against the spread of smoke and fire in the event of a fire inside the cabinet
- Minimising the risk to people from the possible release of gases that burn explosively or are toxic from the cabinet
- Signalling of critical conditions inside the safety cabinet (for people in the danger zone and emergency services) and, where applicable, control of the existing fire protection systems
Certified battery charging cabinet: Pro model with 90 minutes’ fire protection
The Safe Pro cabinet model offers certified fire protection to the highest standards and bears the recognised GS mark (Certified Safety). With its high Fire resistance of 90 minutes the system ensures maximum protection in an emergency.
Should an uncontrollable chain reaction or a fire occur inside a battery cell, the risk is contained within the battery cabinet thanks to its high fire resistance. In the event of an emergency, the system also automatically cuts off the power supply and ventilation to completely stop any further flow of energy.
The Safe Pro battery cabinet therefore offers you reliable protection in both respects. It effectively prevents flames from spreading to the surrounding area, thereby avoiding additional, unpredictable risks to your business. With this safety system, the GS-certified Pro model provides enhanced fire protection and safeguards your business and your staff in the event of an emergency.
LaCont lithium-ion battery cabinets
We offer a range of models for the active and passive storage of lithium-ion batteries, with a primary focus on fire safety









